Dimensions and tolerances EN 10253-4 (DIN 2617)

Ø DN Ø D
15 21,3

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%, max +/- 0,5 mm
DIN 2617 | *:+/- 0,4 mm

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):25 (17.5) +/-4

20 26,9

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%, max +/- 0,5 mm
DIN 2617 | *:+/- 0,4 mm

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):25 +/-4

25 33,7

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%, max +/- 0,5 mm
DIN 2617 | *:+/- 0,4 mm

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):38 (25) +/-4

32 42,4

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%, max +/- 0,5 mm
DIN 2617 | *:+/- 0,4 mm

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):38 +/-4

40 48,3

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%, max +/- 0,5 mm
DIN 2617 | *:+/- 0,4 mm

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):38 +/-4

50 60,3

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%, max +/- 0,5 mm
DIN 2617 | *:+/- 0,4 mm

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):38 +/-4

65 76,1

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%, max +/- 0,5 mm
DIN 2617 | *:+/- 0,4 mm

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):38 +/-4

80 88,9

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%, max +/- 0,5 mm
DIN 2617 | *:+/- 0,4 mm

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):51 +/-4

100 114,3

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,5 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):64 +/-4

125 139,7

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,5 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):76 +/-7

150 168,3

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,5 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):89 +/-7

200 219,1

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):102 +/-7

250 273,0

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):127 +/-7

300 323,9

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):152 +/-7

350 355,6

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):165 +/-7

400 406,4

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):178 +/-7

450 457,0

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):203 +/-7

500 508,0

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):229 +/-7

600 610,0

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):-12,5% /+15%

Height
K (h):267 +/-7

700 711,0

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):T<=10mm: -0,35mm /+15%T>10mm:-0,5mm /+15%

Height
K (h):267 290 (a) +/-7 (+/-10)

800 813,0

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):T<=10mm: -0,35mm /+15%T>10mm:-0,5mm /+15%

Height
K (h):267 330 (b) +/-10

900 914,0

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):T<=10mm: -0,35mm /+15%T>10mm:-0,5mm /+15%

Height
K (h):267 370 (c) +/-10

1000 1016,0

D_INT
Ø internal:D – 2 x w.t

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2617:+/-1%
DIN 2617 | *:+/- 0,6 %

Tolerance on wall thickness
T (s1):T<=10mm: -0,35mm /+15%T>10mm:-0,5mm /+15%

Height
K (h):305 420 (d) +/-10

Unless otherwise indicated, dimensions are in mm.
Dimensions in brackets are valid only for DIN 2617.

Diameters:
Tolerances on outside diameter shall be measured at the welding ends.
* Options that have to be specified in the order.

Out of roundness:
The out of roundness (0) shall be calculated in percentage, using the following equation:
0= (Dmax-Dmin)/Dx100, where:
Dmax = max. outside diameter D, measured in the same plane, in mm;
Dmin = min. outside diameter D, measured in the same plane, in mm;
D = specified outside diameter, in mm.
For fittings of outside diameter D ≤ 406,4 mm, out-of-roundness, shall be included in the limits of the diameter.
For fittings of outside diameter D > 406,4 mm and with D/T less than or equal to 100, out of roundness shall not exceed 2 %.
For fittings with a D/T ratio > 100 the values for out of roundness shall be agreed at the time of enquiry and order.
For DIN 2617 see page 61 (DIN 2609).

(a) DIN 2617, wall thickness > 25 mm
(b) DIN 2617, wall thickness > 17,5 mm
(c) DIN 2617, wall thickness > 10 mm
(d) DIN 2617, wall thickness > 14,2 mm

On request, we can produce caps according to DIN 28013.


Browse catalog