EN 10253-4 (DIN 2616) - Dimensions and tolerances

Ø DN x DN1 Ø D x D1
20 x 15 26,9 x 21,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:38 +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

25 x 20 33,7 x 26,9

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:51 (50) +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

25 x 15 33,7 x 21,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:51 (50) +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

32 x 25 42,4 x 33,7

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:51 (50) +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

32 x 20 42,4 x 26,9

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:51 (50) +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

32 x 15 42,4 x 21,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:51 (50) +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

40 x 32 48,3 x 42,4

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:64 +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

40 x 25 48,3 x 33,7

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:64 +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

40 x 20 48,3 x 26,9

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:64 +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

50 x 40 60,3 x 48,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:76 +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

50 x 32 60,3 x 42,4

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:76 +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

50 x 25 60,3 x 33,7

Ø interno
D – 2 x w.t.

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:76 +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

65 x 50 76,1 x 60,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:89 (90) +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

65 x 40 76,1 x 48,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:89 (90) +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

65 x 32 76,1 x 42,4

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:89 (90) +/-2 (+/-2,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

80 x 65 88,9 x 76,1

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%
Length
L:89 (90) +/-2 (+/-3)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

80 x 50 88,9 x 60,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:89 (90) +/-2 (+/-3)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

80 x 40 88,9 x 48,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%, max +/- 0,5 mm
DIN 2616 | *:+/- 0,4 mm

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:89 (90) +/-2 (+/-3)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

100 x 80 114,3 x 88,9

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,5 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:102 (100) +/-2 (+/-3)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

100 x 65 114,3 x 76,1

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,5 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:102 (100) +/-2 (+/-3)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

100 x 50 114,3 x 60,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,5 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:102 (100) +/-2 (+/-3)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

125 x 100 139,7 x 114,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,5 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:127 +/-2 (+/-3,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

125 x 80 139,7 x 88,9

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,5 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:127 +/-2 (+/-3,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

125 x 65 139,7 x 76,1

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,5 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:127 +/-2 (+/-3,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

150 x 125 168,3 x 139,7

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,5 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:140 +/-2 (+/-3,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

150 x 100 168,3 x 114,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,5 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:140 +/-2 (+/-3,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

150 x 80 168,3 x 88,9

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,5 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:140 +/-2 (+/-3,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

200 x 150 219,1 x 168,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:152 +/-2 (+/-3,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

200 x 125 219,1 x 139,7

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:152 +/-2 (+/-3,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

200 x 100 219,1 x 114,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:152 +/-2 (+/-3,5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

250 x 200 273 x 219,1

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:178 +/-5 (+/-4)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

250 x 150 273 x 168,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:178 +/-5 (+/-4)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

250 x 125 273 x 139,7

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:178 +/-5 (+/-4)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

300 x 250 323,9 x 273

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:203 +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

300 x 200 323,9 x 219,1

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:203 +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

300 x 150 323,9 x 168,3

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:203 +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

350 x 300 355,6 x 323,9

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:330 +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

350 x 250 355,6 x 273

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:330 +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

350 x 200 355,6 x 219,1

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:330 +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

400 x 350 406,4 x 355,6

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:356 (355) +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

400 x 300 406,4 x 323,9

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:356 (355) +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

400 x 250 406,4 x 273

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:356 (355) +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

450 x 400 457 x 406,4

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:381 +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

450 x 350 457 x 355,6

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:381 +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

450 x 300 457 x 323,9

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:381 +/-5 (+/-5)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

500 x 400 508 x 457

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:508 +/-5 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

500 x 400 508 x 406,4

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:508 +/-5 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

500 x 350 508 x 355,6

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:508 +/-5 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

600 x 500 610 x 508

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:508 +/-5 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

600 x 450 610 x 457

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:508 +/-5 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

600 x 400 610 x 406,4

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:-12,5% / +15%

Length
L:508 +/-5 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

700 x 600 711 x 610

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-5 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

700 x 500 711 x 508

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-5 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

700 x 450 711 x 457

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-5 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

800 x 700 813 x 711

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-10 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

800 x 600 813 x 610

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-10 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

800 x 500 813 x 508

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-10 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

900 x 800 914 x 813

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-10 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

900 x 700 914 x 711

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-10 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

900 x 600 914 x 610

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-10 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

1000 x 900 1016 x 914

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-10 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

1000 x 800 1016 x 813

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-10 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

1000 x 700 1016 x 711

Ø interno
D – 2 x w.t.

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:+/-1% or 0,5 mm whichever is the greater
EN 10253-4 | D3*:+/-0,75% or 0,3 mm whichever is the greater
EN 10253-4 | D4*:+/-0,5% or 0,1 mm whichever is the greater
DIN 2616:+/-1%
DIN 2616 | *:+/- 0,6 %

Tolerance on wall thickness
T:T<=10 mm: -0,35 mm / +15% Length
L:610 +/-10 (+/-6)

Alignment
X(Q***):X = 1 % of the outside diameter at the point measured or 1 mm, whichever is the greater

Ø interno

Tolerance on Diameter (D/ID)
EN 10253-4 | D2:
EN 10253-4 | D3*:
EN 10253-4 | D4*:
DIN 2616:
DIN 2616 | *:

Tolerance on wall thickness
T:T>10 mm: -0,5 mm / +15%

Length
L:

Alignment
X(Q***):

Unless otherwise indicated, dimensions are in mm. Dimensions in brackets are valid only for DIN 2616.

Diameters:
Tolerances on outside diameter shall be measured at the welding ends. In order to guarantee the regular flow of the fluid through the fitting, the internal diameter in any section of the fitting shall be above 80 % of the internal diameter at the welding ends. * Options that have to be specified in the order.

Out of roundness:
The out-of-roundness (0) shall be calculated in percentage, using the following equation: 0= (Dmax-Dmin)/Dx100, where: Dmax = max. outside diameter D, measured in the same plane, in mm; Dmin = min. outside diameter D, measured in the same plane, in mm; D = specified outside diameter, in mm. For fittings of outside diameter D ≤ 406,4 mm, out-of-roundness, shall be included in the limits of the diameter. For fittings of outside diameter D > 406,4 mm and with D/T less than or equal to 100, out-of-roundness shall not exceed 2 %. For fittings with a D/T ratio > 100 the values for out-of-roundness shall be agreed at the time of enquiry and order. For DIN 2616 see page 61 (DIN 2609).

Out of squareness: *** DIN 2616, subject to agreement can be reduced to 0,5 % with a maximum of 0,5 mm